FLECHT low flooding rate skewed test series data report

Description

The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec. and with electrically heated rod bundles which had cosine and top skewed axial power profiles. The top-skewed axial power profile test series has now been successfully completed and is here reported. For these tests the rod bundle was enclosed in a low mass cylindrical housing which would minimize the wall housing effects encountered in the cosine test series. These tests examined the effects of initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, rod peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in runs which met the test specifications are reported here, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, and exhaust steam and liquid carryover rates

Availability note (English)

MF available from INIS under the Report Number; Westinghouse Electric Corp., Pittsburgh, PA.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR

Publishing Information

Imprint Pagination
v p.
Report number
WCAP--9108