Published January 2024 | Version v1
Journal article Open

Accuracy Evaluation of Monte Carlo Simulation Results Using ENDF/B‐VIII.0 and JENDL‐5 Libraries for 10 MWth Micro Heat Pipe‐Cooled Reactor

  • 1. Department of Mechanical and Nuclear Engineering, University of Sharjah, P.O. Box, Sharjah 27272, UAE
  • 2. Research Institute of Sciences and Engineering, University of Sharjah, P.O. Box, Sharjah 27272, UAE
  • 3. VNU University of Science, Vietnam National University, 334 Nguyen Trai, Tanh Xuan, Hanoi 120-034, Vietnam

Description

The micro heat pipe‐cooled reactor is an innovative type of reactor that utilizes heat pipes to cool its core. It consists of a reactor core, an energy conversion system, shielding, and a heat removal system. This reactor shows great potential as a viable option for supplying electricity in remote areas. By incorporating a monolithic core with heat pipes and an efficient heat conversion system, this reactor design eliminates the need for a main pipeline, circulating pump, and auxiliary equipment, resulting in a cost‐effective, compact, and transportable system. The monolithic reactor design has undergone significant advancements in neutronics and thermal hydraulics. This article focuses on evaluating the impact of the latest released nuclear data libraries, ENDF/B‐VIII.0 and JENDL‐5, on calculated neutronics and kinetics parameters. The total keff uncertainty was propagated and found to be significant for both recently evaluated nuclear data libraries (678.52 pcm for ENDF/B‐VIII.0 and 525.91 pcm for JENDL‐5, respectively). The total uncertainty originated from nuclear data was evaluated for total ν, reaction cross sections, and angular distributions in the case of JENDL‐5, and for ENDF/B‐VIII.0, uncertainty from angular distributions was not included because of the unavailability of its multigroup structure covariance matrices. The results reveal that the largest contributor for ENDF/B‐VIII.0 is 235U total (409.18 pcm), while that for JENDL‐5 is 56Fe capture cross section (361.93 pcm). For the kinetic parameter's uncertainty, the impact on the total βeff, leff, and λeff simulation results was found to be not significant (about 1%).

Files

10.1155_2024_5565346.pdf

Files (2.7 MB)

Name Size Download all
md5:64e6155d713dd0405f63f77d4e839b37
2.7 MB Preview Download

System files (44.5 kB)

Name Size Download all

Additional details

Identifiers

DOI
10.1155/2024/5565346;
Crossref Funder ID
10.13039/100016714;

Publishing Information

Journal Title
Science and Technology of Nuclear Installations
Journal Volume
2024
Journal Issue
1
ISSN
1687-6075

Optional Information

Copyright
© Author(s)
Contract/Grant/Project number
230204082261
Notes
Record automatically processed
Funding organization