Published 1992
| Version v1
Book
Sludge distribution in a scale model recirculating steam generator
Creators
- 1. Nuclear Services Div., Westinghouse Electric Corp., Pensacola, FL (United States)
- 2. Westinghouse Electric Corp., Pittsburgh, PA (United States). Nuclear Services Div.
Description
A scale model of the Westinghouse Model F steam generator was operated for three years under similar operating conditions to those of a full scale steam generator. As part of the decommissioning the scale model, the steam generator was taken apart and inspected. Photographs and descriptions of sludge deposition patterns from the tube bundle were recorded. This paper describes the sludge deposit in patterns and discusses the correlation of these deposition patterns with steam generator thermal hydraulic conditions
Additional details
Publishing Information
- Publisher
- American Society of Mechanical Engineers.
- Imprint Place
- New York, NY (United States)
- ISBN
- 0-7918-0796-7
- Imprint Title
- Proceedings of steam generator sludge deposition in recirculating and once through steam generator upper tube bundle and support plates
- Imprint Pagination
- 93 p.
- Journal Page Range
- p. 75-82.
Conference
- Title
- 1992 international joint power generation conference.
- Dates
- 18-22 Oct 1992.
- Place
- Atlanta, GA (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24033533
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DECOMMISSIONING; DEPOSITION; HYDRAULICS; INSPECTION; SCALE MODELS; SLUDGES; STEAM GENERATORS
- Descriptors DEC
- BOILERS; STRUCTURAL MODELS; VAPOR GENERATORS
Optional Information
- Secondary number(s)
- CONF-921004--.