Published 1989
| Version v1
Journal article
Mathematical models of calibration procedures of radioisotope gauges
Description
A general review is presented of radioisotope gauges used for industrial purposes. Basing on the earlier developed instruments using different effects of the interaction of radiation with a substance, an estimation is made of their mathematical models. It has been stated that the least value of remainder variance is obtained when the calibration procedure is modelled by a logarithmic function. (author)
Additional details
Additional titles
- Original title (Polish)
- Modele matematyczne procedur wzorcowania radioizotopowej aparatury pomiarowej
Publishing Information
- Journal Title
- Pomiary Automatyka Kontrola
- Journal Volume
- 35
- Journal Issue
- 5
- Series
- Pomiary Autom. Kontrola.
- Journal Page Range
- 97-101
- ISSN
- 0032-4140
- CODEN
- PAUKA
INIS
- Country of Publication
- Poland
- Country of Input or Organization
- Poland
- INIS RN
- 23012345
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CALIBRATION; INDUSTRY; MATHEMATICAL MODELS; RADIOMETRIC GAGES; REVIEWS
- Descriptors DEC
- DOCUMENT TYPES; MEASURING INSTRUMENTS