Reproducibility of high-resolution MRI for the middle cerebral artery plaque at 3 T
- 1. Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, Guangzhou, Guangdong 510080 (China)
- 2. Department of Neurology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, Guangzhou, Guangdong 510080 (China)
- 3. Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China)
Description
Purpose: To assess the reproducibility of HR-MRI for the identification of MCA atherosclerotic plaque components and quantification of stenosis. Materials and methods: Seventy-three consecutive subjects who initially had ischemic stroke or asymptomatic MCA stenosis (>50%) were enrolled in the study. All subjects were scanned using 3.0 T MRI. Two independent readers reviewed all images and one reader reevaluated all images four weeks later. The tissue components of plaques were analyzed qualitatively and the vessels were quantitative measured. Results: HR-MRI displayed the artery wall and lumen clearly. The intra-observer reproducibility was excellent for the identification of plaques (kappa [κ] = 0.96; 95% CI: 0.83–1.04) and contrast enhancement (κ = 0.89; 0.78–0.95); it was substantial for intra-plaque hemorrhage (κ = 0.79; 0.57–0.96) and the fibrous cap (κ = 0.65; 0.42–0.86). The inter-observer reproducibility was excellent for plaques (κ = 0.92; 0.73–1.06), substantial for contrast enhancement (κ = 0.80; 0.65–0.93), intra-plaque hemorrhage (κ = 0.68; 0.47–0.92) and moderate for the fibrous cap (κ = 0.58; 0.44–0.79). Both intra-observer and inter-observer reproducibility were excellent for quantitative vessel, lumen and wall measurements with intraclass correlation coefficients ranging from 0.91 to 0.97 and 0.87 to 0.96, respectively. However, vessel and wall areas and the intervals defined by the Bland–Altman plots were wide in comparison to the mean. Conclusions: The identification of MCA atherosclerotic plaque components and the quantification of vessel and lumen measurements are reproducible. The reproducibility is overall acceptable. HR-MRI may provide a useful tool for clinical risk evaluation in MCA atherosclerosis
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2013.10.003Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2013.10.003;
- PII
- S0720-048X(13)00532-9;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 83
- Journal Issue
- 1
- Journal Page Range
- p. e49-e55
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47005222
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ANIMAL TISSUES; ARTERIOSCLEROSIS; CEREBRAL ARTERIES; COMPARATIVE EVALUATIONS; CORRELATIONS; HEMORRHAGE; ISCHEMIA; NMR IMAGING; RESOLUTION
- Descriptors DEC
- ANEMIAS; ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; HEMIC DISEASES; ORGANS; PATHOLOGICAL CHANGES; SYMPTOMS; VASCULAR DISEASES
Optional Information
- Copyright