Published 2006 | Version v1
Miscellaneous Open

Microstructural characterization of porous materials by X-ray microtomography and gamma ray transmission techniques

Description

This work presents the application of the X-ray microtomography and gamma ray transmission techniques for the microstructure characterization of different kinds of materials. Total porosity, pore size distribution and the two point correlation functions were measured. The two point correlation function, which allows the reconstruction of 3D models, was carried out for two samples. Seven ceramic tablets of Alumina (Al2O3), seven tablets of Boron Carbide (B4C), three samples of sedimentary rocks and one sample of Titanium foam were analyzed. The experimental set up for the Gamma Ray Transmission technique consisted of: a 2'' x 2'' crystal NaI(Tl) detector, an 241 Am radioactive source (59,53 keV, 100 mCi), an automatic micrometric table for the sample XZ movement and standard gamma spectrometry electronics. Two microtomography systems were used: a Fein Focus system, constituted by an X-ray tube, operated at 160 kV and 0.3 to 1.1 mA, a CCD camera and the movement sample system, and a Skyscan system, model 1072, with a X-ray tube operated at 100 kV and 100μA, and a CCD camera. The ceramic tablets, analyzed by the gamma ray transmission technique presented results for most of the porosities data with smaller confidence intervals and inside the intervals supplied by the tablets manufacturer. The Titanium porous sample was analyzed by the two techniques, its microtomography images achieved a resolution of 17μm, obtained employing the Fein Focus system. For both techniques, this sample showed high porosity, which allows its application for this purpose. The sandstones samples were analyzed by the Skyscan system, achieving resolutions of 19μm, 11μm and 3.8μm for each sample, respectively. The resolutions of 11μm and 3.8μm were the ones that generated better 2D sections for the respective samples and, consequently, more reliable porosities. The 3.8μm resolution was the one that best quantified the pore size distribution data, showing information not shown by the 11μm resolution, showing that pores with 15 to 45μm radius are predominant, constituting 57% of the porous phase of this sample, and 1 % are just constituted by pores with radius up to 3.8μm. These results show that resolution better than 3.8μm could be necessary only for specific cases. (author)

Availability note (English)

Available from INIS in electronic form

Files

39120243.pdf

Files (5.4 MB)

Name Size Download all
md5:16929b7e45f1bc04b15c688d731229ae
5.4 MB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Caracterizacao da microestrutura de materiais porosos por microtomografia de raios X e transmissao de raios gama

Publishing Information

Imprint Pagination
120 p.
Report number
INIS-BR--4464

Optional Information

Notes
refs., 82 figs., 7 tabs.