Published 1980 | Version v1
Report

Criticality safety in transporting spent fuel

Creators

Description

The shipping packaging must meet the safety requirements of 10 CFR part 71. To make the place at least 0.5 inches of water between poison plates. Aspects of the most reactive credible configuration are discussed. 5 figures

Additional details

Publishing Information

Imprint Title
Nuclear criticality safety
Journal Page Range
p. 241-247.
Report number
SAND--80-1675

Conference

Title
Nuclear criticality safety topical meeting.
Dates
8 - 10 Apr 1980.
Place
El Paso, TX, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12588571
Subject category
S42: ENGINEERING; S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCIDENTS; BURNABLE POISONS; CASKS; CRITICALITY; FUEL ELEMENTS; SAFETY
Descriptors DEC
CONTAINERS; NEUTRON ABSORBERS; NUCLEAR POISONS; REACTOR COMPONENTS; REACTOR MATERIALS