Simulation of adjuster withdrawal in Darlington Unit 4
- 1. AMEC NSS Limited, Toronto, Ontario (Canada)
- 2. Ontario Power Generation, Clarington, Ontario (Canada)
Description
Physics simulations in safety analyses are generally performed using a bundle irradiation distribution that is consistent with an approximate time-average configuration. In this paper, three assessments of a spurious adjuster withdrawal event at Darlington are performed with RFSP. The simulations are performed using a time-average irradiation distribution and the SORO predicted irradiation distribution just prior to the actual event. In all three of the assessments it is shown that the results are quite insensitive to the assumed irradiation distribution. This supports the approach of assuming a time-average irradiation distribution in safety analyses. (author)
Additional details
Publishing Information
- Publisher
- Canadian Nuclear Society
- Imprint Place
- Toronto, Ontario (Canada)
- ISBN
- 978-1-926773-04-9
- Imprint Title
- Nuclear at Niagara. 32nd Annual Canadian Nuclear Society conference and 35th CNS/CNA student conference
- Imprint Pagination
- 136 Megabytes
- Journal Page Range
- [20 p.]
Conference
- Title
- 32. Annual Canadian Nuclear Society conference; 35. CNS/CNA student conference
- Dates
- 5-8 Jun 2011
- Place
- Niagara Falls, Ontario (Canada)
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 45046175
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DARLINGTON SITE; IRRADIATION; RADIATION DOSE DISTRIBUTIONS; SAFETY ANALYSIS; SIMULATION
- Descriptors DEC
- REACTOR SITES
Optional Information
- Notes
- 1 ref., 3 tabs., 16 figs.