Example motion sensor test results using the Sandia intruder motion simulator
Description
Sandia National Laboratories at Albuquerque (SNLA) has designed and built a system to provide repeatability in environmental testing of motion sensors. This system, called Sandia Intruder Motion Simulator (SIMS), is used to acquire much of the data now collected on sensors in this laboratory. This paper reports the results of environmental evaluations performed on several different types of motion sensors using the SIMS. 12 figures
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE84014988.
Files
Additional details
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- SAND--84-0538C
Conference
- Title
- 25. annual meeting of the Institute of Nuclear Materials Management.
- Dates
- 15-18 Jul 1984.
- Place
- Columbus, OH (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16015334
- Subject category
- S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION;
- Resource subtype / Literary indicator
- Conference, Numerical Data
- Descriptors DEI
- EXPERIMENTAL DATA; MOTION DETECTION SYSTEMS; PERFORMANCE TESTING; RESPONSE MODIFYING FACTORS; SENSITIVITY
- Descriptors DEC
- DATA; INFORMATION; NUMERICAL DATA; TESTING
Optional Information
- Secondary number(s)
- CONF-840734--9.