Non-invasive determination of the irradiation dose in fingers using low-frequency EPR
Creators
- 1. Laboratory of Biomedical Magnetic Resonance, Universite catholique de Louvain, UCL, Avenue Hippocrate, 10, B-1200 Brussels (Belgium)
- 2. Service de Dosimetrie Externe, Departement de Radioprotection et de Protection de l'Homme, Institut de Radioprotection et de Surete Nucleaire, IRSN, BP no 17, F-92262 Fontenay-aux-Roses Cedex (France)
Description
Several reports in the literature have described the effects of radiation in workers who exposed their fingers to intense radioactive sources. The radiation injuries occurring after local exposure to a high dose (20 to 100 Gy) could lead to the need for amputation. Follow-up of victims needs to be more rational with a precise knowledge of the irradiated area that risks tissue degradation and necrosis. It has been described previously that X-band electron paramagnetic resonance (EPR) spectroscopy could be used to assess the dose in irradiated amputated fingers. Here, we propose the use of low-frequency EPR spectroscopy to evaluate non-invasively the absorbed dose. Low-frequency microwaves are indeed less absorbed by water and penetrate more deeply into living material (∼10 mm in tissues using 1 GHz spectrometers). This work presents preliminary results obtained with baboon and human fingers compared with human dry phalanxes placed inside a surface-coil resonator. The EPR signal increased linearly with the dose. The ratio of the slopes of the dry bone to whole finger linear regression lines was around 5. The detection limit achievable with the present spectrometer and resonator is around 60 Gy, which is well within the range of accidentally exposed fingers. It is likely that the detection limit could be improved in the future, thanks to further technical spectrometer and resonator developments as well as to appropriate spectrum deconvolution into native and dosimetric signals
Availability note (English)
Available online at http://stacks.iop.org/0031-9155/49/2891/pmb4_13_009.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/Additional details
Identifiers
- URL
- http://stacks.iop.org/0031-9155/49/2891/pmb4_13_009.pdf; http://www.iop.org/;
- DOI
- 10.1088/0031-9155/49/13/009;
- PII
- S0031-9155(04)75593-1;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 49
- Journal Issue
- 13
- Journal Page Range
- p. 2891-2898
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35068849
- Subject category
- S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS;
- Descriptors DEI
- BABOONS; BIOLOGICAL RADIATION EFFECTS; NECROSIS; RADIATION DOSES; RADIATION INJURIES; RESONATORS; SPECTROMETERS
- Descriptors DEC
- ANIMALS; BIOLOGICAL EFFECTS; BIOLOGICAL RADIATION EFFECTS; DISEASES; DOSES; ELECTRONIC EQUIPMENT; EQUIPMENT; INJURIES; MAMMALS; MEASURING INSTRUMENTS; MONKEYS; PATHOLOGICAL CHANGES; PRIMATES; RADIATION EFFECTS; VERTEBRATES