Monte Carlo neutron fluence calculations, activation measurements and spectrum adjustment for the KORPUS dosimetry experiment

Description

KORPUS is an irradiation facility located at the lateral core surface of the 6 MW experimental reactor RBT-6 in Dimitrovgrad. In this work the KORPUS irradiation experiment has been used to demonstrate the capability of the pressure vessel dosimetry methodology developed in Rossendorf to solve these problems. At the same time the experiments were used to test recent improvements of this methodology including a new procedure for treatment of elastic scattering in the Monte Carlo code TRAMO and a new multispectrum version of the adjustment code. By means of a series of calculations the influence of model and data approximations were investigated aiming at an evaluation of the uncertainties of the calculations. Further, uncertainty investigations were carried out in connection with spectrum adjustment resulting in covariances of spectra, measured reaction rates and fluence integrals. (orig.)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Forschungszentrum Rossendorf, Institute of Safety Research. Annual report 1999

Additional details

Publishing Information

Imprint Title
Forschungszentrum Rossendorf, Institute of Safety Research. Annual report 1999
Imprint Pagination
161 p.
Journal Page Range
p. 95-102
ISSN
1437-322X
Report number
FZR--284

Optional Information