Published 2007 | Version v1
Miscellaneous

Evaluation of a coolant injection into the in-vessel with a RCS depressurization by using SCDAP/RELAP5

  • 1. Korea Atomic Energy Research Institute, Yuseong, Daejeon (Korea, Republic of)

Description

As part of the evaluations of a severe accident management strategy, a coolant injection in the vessel with a reactor coolant system (RCS) depressurization has been evaluated by using the SCDAP/RELAP5 computer code. Two high pressure sequences of a small break loss of coolant accident (LOCA) without safety injection (SI) and a total loss of feed water (LOFW) accident have been analyzed in optimized power reactor OPR-1000. The SCDAP/RELAP5 results have shown that only one train operation of a high pressure safety injection at 30,000 seconds with a RCS depressurization by using one condenser dump valve at 6 minutes after an entrance of the severe accident management guidance prevents a reactor vessel failure for the small break LOCA without SI. In this case, only train operation of the low pressure safety injection (LPSI) without the high pressure safety injection (HPSI) does not prevent a reactor vessel failure. Only one train operation of the HPSI at 20,208 seconds with a RCS depressurization by using two safety depressurization system valves at 40 minutes after an initial opening of the safety relief valve prevents a reactor vessel failure for the total LOFW. (authors)

Availability note (English)

Available from: SFEN, 5 rue des Morillons, 75015 Paris (France)

Additional details

Publishing Information

Imprint Pagination
7 p.
Report number
INIS-FR--08-0467

Conference

Title
ICAPP 2007 - International congress on advances in nuclear power plants. The nuclear renaissance at work
Dates
13-18 May 2007
Place
Nice Acropolis (France)

Optional Information

Notes
11 refs.