Evolution of management and performance of the Point Lepreau steam generators
Creators
- 1. NB Power Nuclear, Lepreau, New Brunswick (Canada)
- 2. Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)
Description
The Point Lepreau steam generators have been in service since 1983 when the plant was commissioned. During the first thirteen years of operation, Point Lepreau steam generator maintenance issues led to 3-4% unplanned plant incapability. Steam generator fouling, corrosion, and the introduction of foreign materials during maintenance led to six tube leaks, two unplanned outages, two lengthy extended outages, and degraded thermal performance during this period. In recognition of the link between steam generator maintenance activities and plant performance, improvements to steam generator management activities have been continuously implemented since 1987. This paper reviews the evolution of steam generator management activities at Point Lepreau and the resulting improved trends in performance. Plant incapability from unplanned steam generator maintenance has been close to zero since 1996. The positive trends have provided a strong basis for the management strategies developed for post-refurbishment operation, which are discussed in another paper at this conference. (author)
Additional details
Publishing Information
- Publisher
- Canadian Nuclear Society
- Imprint Place
- Toronto, Ontario (Canada)
- ISBN
- 0-919784-87-9
- Imprint Title
- Fifth CNS international steam generator conference
- Imprint Pagination
- 248 Megabytes
- Journal Page Range
- [16 p.]
Conference
- Title
- 5. CNS international steam generator conference. Proceedings
- Dates
- 26-29 Nov 2006
- Place
- Toronto, Ontario (Canada)
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 38098290
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CORROSION; MAINTENANCE; OUTAGES; PERFORMANCE; POINT LEPREAU-1 REACTOR; REPAIR; STEAM GENERATORS; THERMAL DEGRADATION
- Descriptors DEC
- BOILERS; CANDU TYPE REACTORS; CHEMICAL REACTIONS; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; NATURAL URANIUM REACTORS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS
Optional Information
- Notes
- Paper 1B001; 1 tab., 7 figs. Slide presentation also available.