Published October 1979
| Version v1
Report
Restricted
Power cooling mismatch test series Test PR-1: experiment operating specification
Description
The facility operating specifications are described for the PCM-RIA-1 (PR-1) Test. Test PR-1 will involve: steady state operation to provide power calibration information, a series of power cooling mismatch (PCM) DNB cycles induced by reduction in coolant flow rate and a series of Reactivity Insertion (RIA) power excursions. In addition, steady state and power oscillation gap conductance data will be obtained to extend the data base for evaluating the effects of fuel pellet density, initial gap width, and gap gas composition on gap conductance
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01.
Files
Additional details
Additional titles
- Augmented title (English)
- BWR
Publishing Information
- Imprint Pagination
- 59 p.
- Report number
- EGG-TFBP--5027
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 11531371
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- BWR TYPE REACTORS; EXCURSIONS; FUEL RODS; HEAT TRANSFER; HYDRAULICS; PERFORMANCE TESTING; POWER-COOLING-MISMATCH ACCIDEN; REACTOR SAFETY
- Descriptors DEC
- ACCIDENTS; ENERGY TRANSFER; FUEL ELEMENTS; REACTOR ACCIDENTS; REACTOR COMPONENTS; REACTORS; SAFETY; TESTING; WATER COOLED REACTORS; WATER MODERATED REACTORS