Measuring time-dependent neutron flux from 14MeV neutron generators by radioactivation techniques

  • 1. Fraunhofer-Gesellschaft zur Foerderung der Angewandten Forschung e.V., Euskirchen (Germany, F.R.). Inst. fuer Naturwissenschaftlich-Technische Trendanalysen

Description

The neutron fluence from the 14MeV neutron generator is determined by activation foils and fission chambers. U238 fission chambers are used to record the fluctuation of the neutron flux in time; this measurement is used to calculate the buildup and the decay of foil activity. Then from the foil activity the neutron fluence can be determined. This method is more accurate than the activation method alone since temporal variations of the neutron flux are taken into account. It turns out that with neutron flux variations by a factor of 2 the simple activation method may result in 60% error in neutron fluency. 1 ref., 5 figs. (Author)

Part of:
4. European congress and 13. regional congress of IRPA

Additional details

Additional titles

Original title (German)
Measuring time-dependent neutron flux from 14MeV neutron generators by radioactivation techniques

Publishing Information

Imprint Title
4. European congress and 13. regional congress of IRPA
Imprint Pagination
909 p.
Journal Page Range
p. 609-613.
Report number
OEVS-Mitteilung--1988

Conference

Title
4. European congress and 13. regional congress of IRPA.
Dates
15-19 Sep 1986.
Place
Salzburg (Austria).

INIS

Country of Publication
Austria
Country of Input or Organization
Austria
INIS RN
20042617
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCURACY; ACTIVATION DETECTORS; CORRECTIONS; FOILS; MEASURING METHODS; NEUTRON FLUENCE; NEUTRON GENERATORS
Descriptors DEC
MEASURING INSTRUMENTS; NEUTRON DETECTORS; NEUTRON SOURCES; PARTICLE SOURCES; RADIATION DETECTORS; RADIATION SOURCES