Published June 1998 | Version v1
Journal article

Surface activity and dose rate distribution inside 4-th reactor hall of Chernobyl NPP

Description

A Gamma Locator designed to conduct contamination surveys inside the reactor hall of the Chernobyl NNP 4-th unit is developed. The device consists of detector head and remote control computer connected with a cable (> 150 m). The detector head is a collimated scintillator-based gamma-ray detector. It is installed on a scanning unit and is placed inside the reactor hall. The Gamma Locator scans all hall surfaces with a certain angle step and measures quantum flux from these directions. These data are used to determine the effective surface activity of contaminated surfaces. A distance between the detector head and surveyed surface is measured by a laser distance device. There is a small CCD camera inside the collimator. It obtains a visible image of the measured surface. An exposed dose rate distribution within the investigated volume is reconstructed by using the measured 137Cs effective surface activity

Additional details

Publishing Information

Journal Title
IEEE Transactions on Nuclear Science
Journal Volume
45
Journal Issue
3Pt1
Journal Page Range
p. 986-991
ISSN
0018-9499
CODEN
IETNAE

Conference

Title
Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference
Dates
11-13 Nov 1997
Place
Albuquerque, NM (United States)

Optional Information

Secondary number(s)
CONF-971147--