Published May 1977
| Version v1
Report
Restricted
Portable HAD
Description
The control unit is designed to power the General Monitors hydrocarbon gas detector which is presently used at SLAC by the LH2 Target group as their standard Hazardous Atmosphere Detector (HAD). The sensor requires a heater current of 330 mA (5 V) to establish the necessary temperature for the device to perform as specified. The sensor has two elements connected in series, one being coated with a proprietary catalyst that causes the gas to burn on the surface of the element, thus increasing the temperature; and since the element is a platinum compound, also increasing the element resistance. Circuit diagrams are presented and discussed
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Additional titles
- Augmented title (English)
- Hazardous Atmosphere Detector for monitoring combustible hydrocarbon gases
Publishing Information
- Imprint Pagination
- 12 p.
- Report number
- SLAC-TN--77-4
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 9389906
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CONTROL SYSTEMS; ELECTRIC BRIDGES; ELECTRONIC CIRCUITS; FIRES; GASES; HEALTH HAZARDS; HYDROCARBONS; MONITORING; SAFETY
- Descriptors DEC
- ELECTRICAL EQUIPMENT; FLUIDS; HAZARDS; ORGANIC COMPOUNDS