Description

A multichannel system of the Hα-line emission detector is developed in order to investigate the neutral particle transport in the Heliotron J plasma. The application of a multianode photomultiplier tube to the filter measurement system enables us to observe the Hα emission profile with 32 chords. The absolute calibration with a standard lamp is performed and the cross-talk between each of the adjoining channels is evaluated to be less than 6%, while the photomultiplier tube has a typical cross-talk of 3% in nominal value. The temporal and spatial profiles of the Hα emission are measured in detail in the plasma breakdown by electron cyclotron heating (ECH). The Hα emission profile in the ECH plasma is calculated by the Monte Carlo simulation using a three-dimensional mesh model. The fueling rates of the wall recycling and the gas puffing are estimated by means of the simulation and the measurement

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
77
Journal Issue
10
Journal Page Range
p. 10E527
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2006 American Institute of Physics