Published September 2001 | Version v1
Report

Initial evaluation of a full breast digital system

  • 1. Radiology Department, Medicine School, Complutense University, Madrid (Spain)
  • 2. Medical Physics Service, San Carlos University Hospital, Madrid (Spain)
  • 3. Diagnostic Radiology Service, San Carlos University Hospital, Madrid (Spain)

Description

Full-field digital mammography systems have been developed for overcoming the limitations of the screen-film mammography. This work is focused on the system from GE Medical Systems (Senographe 2000) which has been recently installed in our institution. The imager consists of a thin Ics:Tl scintillator which is in narrow contact with an array of amorphous silicon detectors mounted in a single panel. The flat-panel detector is integrated in a x-ray system with a high-frequency generator Senographe DM and dual track anode of Mo and Rh with Mo and Rh filtration. The aim of this work is to analyse the defaults exposure factors set at the installation of the x-ray unit. The image quality has been evaluated by using one of the two phantoms recommended in the ACR Accreditation Program. Phantom images were obtained at each of the three available imaging modes: contrast (CNT), standard (STD) and DOSE. While maintaining the defaults of kilovoltage and anode/filter combination, phantom images were obtained at lower dose vales. The contrast noise ratio (CNR) was calculated for each of the low contrast objects (masses) of the phantom images and the detail visibility was also evaluated. The results obtained for both parameters reveal that similar image quality can be obtained with significant reductions of the average glandular dose. (author)

Part of:
Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers

Additional details

Publishing Information

Imprint Title
Radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. Contributed papers
Imprint Pagination
[928 p.]
Journal Issue
no. 7/CD
Series
C and S papers series
Journal Page Range
[5 p.]
ISSN
1562-4153
Report number
IAEA-CSP--7/CD

Conference

Title
International conference on radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy
Dates
26-30 Mar 2001
Place
Malaga (Spain)

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
32065420
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; DOSIMETRY; EVALUATION; IMAGE PROCESSING; MAMMARY GLANDS; NEOPLASMS; PATIENTS; RADIATION DOSES; RADIATION PROTECTION; SIGNAL-TO-NOISE RATIO
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY

Optional Information

Notes
6 refs, 2 figs, 1 tab Imprint:Data in PDF format; Acrobat Reader for Windows 3.x, 95, 98, NT 3.5.1, NT 4.0, MacIntosh and UNIX (SUN, HP, IRIX (SGI), AIX and Digital UNIX) included
Secondary number(s)
IAEA-CN--85-233