Published June 2008 | Version v1
Journal article

Efficacy of a radiation safety education initiative in reducing radiation exposure in the pediatric IR suite

  • 1. University of Cincinnati College of Medicine, Cincinnati, OH (United States)
  • 2. University of Cincinnati Medical Center, Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH (United States)
  • 3. University of Cincinnati Medical Center, Department of Public Health Sciences, Institute for the Study of Health, Cincinnati, OH (United States)

Description

The use of ionizing radiation is essential for diagnostic and therapeutic imaging in the interventional radiology (IR) suite. As the complexity of procedures increases, radiation exposure risk increases. We believed that reinforcing staff education and awareness would help optimize radiation safety. To evaluate the effect of a radiation safety education initiative on IR staff radiation safety practices and patient radiation exposure. After each fluoroscopic procedure performed in the IR suite during a 4-month period, dose-area product (DAP), fluoroscopy time, and use of shielding equipment (leaded eyeglasses and hanging lead shield) by IR physicians were recorded. A lecture and article were then given to IR physicians and technologists that reviewed ALARA principles for optimizing radiation dose. During the following 4 months, those same parameters were recorded after each procedure. Before education 432 procedures were performed and after education 616 procedures were performed. Physician use of leaded eyeglasses and hanging shield increased significantly after education. DAP and fluoroscopy time decreased significantly for uncomplicated peripherally inserted central catheters (PICC) procedures and non-PICC procedures after education, but did not change for complicated PICC procedures. Staff radiation safety education can improve IR radiation safety practices and thus decrease exposure to radiation of both staff and patients. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00247-008-0826-9

Additional details

Identifiers

Publishing Information

Journal Title
Pediatric Radiology
Journal Volume
38
Journal Issue
6
Journal Page Range
p. 669-674
ISSN
0301-0449
CODEN
PDRYA5

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
39067341
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
DOSE RATES; PATIENTS; PEDIATRICS; RADIATION DOSES; RADIATION PROTECTION
Descriptors DEC
DOSES; MEDICINE