Diagnostic reference levels for diagnostic and interventional X-ray procedures in Germany. Update and handling
- 1. Federal Office for Radiation Protection, Neuherberg (Germany). Dept. of Medical and Occupational Radiation Protection
- 2. Paracelsus Medical University, General Hospital Nuremberg (Germany). Institute for Radiology and Nuclear Medicine
- 3. Bochum University (Germany). Diagnostic and Interventional Radiology
Description
Recent developments in medical technology have broadened the spectrum of X-ray procedures and changed exposure practice in X-ray facilities. For this reason, diagnostic reference levels (DRLs) for diagnostic and interventional X-ray procedures were updated in 2016 and 2018, respectively. It is the aim of this paper to present the procedure for the update of the DRLs and to give advice on their practical application. For the determination of DRLs, data from different independent sources that collect dose-relevant data from different facilities in Germany were considered. Seven different weight intervals were specified for classifying pediatric X-ray procedures. For each X-ray procedure considered, the 25th, 50th, and 75th percentile of the respective national distribution of the dose-relevant parameters were determined. Additionally, effective doses that correspond to the DRLs were estimated. In procedures with already existing DRLs before 2016, the values were lowered by circa 20 % on average. Numerous DRLs were established for the first time (9 for interventional procedures, 10 for CT examinations). For dose optimizations even below the new national DRLs, the BfS recommends establishing local reference levels, using dose management software (particularly in CT and interventional radiology), adapting dose-relevant parameters of X-ray protocols to the individual patient size, and establishing internal radiation protection teams responsible for optimizing X-ray procedures in clinical practice. When applying good medical practice and using modern equipment, the median dose values of the nationwide dose distributions can not only be easily achieved but can even be undercut.
Additional details
Additional titles
- Original title (German)
- Diagnostische Referenzwerte für diagnostische und interventionelle Röntgenanwendungen in Deutschland. Aktualisierung und Handhabung
Publishing Information
- Journal Title
- RoeFo - Fortschritte auf dem Gebiet der Roentgenstrahlen und der bildgebenden Verfahren
- Journal Volume
- 191
- Journal Issue
- 8
- Journal Page Range
- p. 739-751
- ISSN
- 1438-9029
- CODEN
- RFGNDO
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 50068207
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ADULTS; BIOMEDICAL RADIOGRAPHY; COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC USES; EFFECTIVE RADIATION DOSES; FEDERAL REPUBLIC OF GERMANY; OPTIMIZATION; PEDIATRICS; RADIATION DOSE DISTRIBUTIONS; RADIATION PROTECTION; SURGERY; X-RAY EQUIPMENT
- Descriptors DEC
- AGE GROUPS; DEVELOPED COUNTRIES; DIAGNOSTIC TECHNIQUES; DOSES; EQUIPMENT; EUROPE; MEDICINE; NUCLEAR MEDICINE; RADIATION DOSES; RADIOLOGY; TOMOGRAPHY; USES; WESTERN EUROPE