Published August 1972 | Version v1
Journal article

Measurements of thoron in the atmosphere

  • 1. Nagoya Univ. (Japan). Faculty of Engineering

Description

A study has been made on a method for calibrating the ionization current to be determined when measuring thoron concentration with an ionization chamber. The ionization current generated by the thoron exhausted from RdTh solution would appear to be controlled mainly by the bubbling velocity in the bottle, and the reciprocal of the current is a linear function of the reciprocal of the velocity. The ionization current was calculated from thoron concentration by taking the following three conditions into consideration: (1) loss of ions by columnar recombination, (2) loss of range by the chamber wall, and (3) the condition of the air flow through the chamber. The calibrated and measured values coincided well with each other. Thoron concentrations in the atmosphere were measured on the university campus in Nov. 1968, and the concentration was found to be 0.3-0.6×10-16Ci/cm3 at 1m above the ground surface. (author)

Availability note (English)

Available from DOI: https://doi.org/10.3327/jaesj.14.415

Additional details

Additional titles

Original title (Japanese)
大気中のトロン濃度の測定

Identifiers

Publishing Information

Journal Title
Nippon Genshiryoku Gakkai-Shi
Journal Volume
14
Journal Issue
8
Journal Page Range
p. 415-421
ISSN
0004-7120

Optional Information

Notes
4372600; This record replaces 04048039