Published 2006 | Version v1
Miscellaneous

Accuracy Adjustment for a Neutron Transmutation Doping of Si Ingots

  • 1. Decon Engineering, Suwon (Korea, Republic of)
  • 2. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Description

HANARO provides two vertical irradiation holes in the D2O reflector region for a Neutron Transmutation Doping (NTD). One of them has been used for a 5 and 6 inch NTD commercial service since 2003 and 2005 respectively. Excellent irradiation uniformity and high accuracy to a target neutron dose have been achieved from the early works of NTD. However, our expected resistivities have exhibited a slightly lower tendency when compared with the measured results by a semiconductor company. To achieve exact neutron irradiations corresponding to the actually measured resistivities, an old K value, which is a constant representing the relationship between the neutron fluence and target resistivity, was investigated and replaced with a new one by analyzing the measured results so far achieved. This paper describes the effects of changing the K value on the irradiation accuracy

Part of:
Proceedings of the KNS autumn meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS autumn meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2006 autumn meeting of the KNS
Dates
2-3 Nov 2006
Place
Kyongju (Korea, Republic of)

Optional Information

Notes
3 refs, 4 figs