Clinical impact of the detector size effect in 3D-CRT

  • 1. Department of Radiation Oncology and Medical Physics, Hospital Universitario de la Princesa, Diego de Leon 62, 28006 Madrid (Spain)
  • 2. Department of Radiation Oncology, Hospital Universitario Ramon y Cajal, Madrid (Spain)

Description

Objective: The detector size artificially increases the measured penumbra of radiotherapy fields. The aim of this work is to determine the influence of the detector size when planning three-dimensional conformal radiation therapy (3D-CRT) treatments. Material and methods: Two anatomical sites of interest in 3D-CRT were studied: prostate and hypophysis chordoma. Conventional 3D-CRT treatments for two cases in these locations were planned with a FOCUS 4.0.0 (Computerized Medical Systems, USA) treatment planning system (TPS) equipped with Fast Fourier Transform Convolution (FFTC) and Multigrid Superposition (MGS) algorithms, making use of beams modelled from radiation profiles measured either with a 2.0 mm diameter detector (PFD3G diode) or with a 5.5 mm diameter detector (PTW-31002 ionisation chamber). These detectors cover up the range of detector sizes commonly used to measure radiation profiles for 3D-CRT. Dose-volume histograms (DVHs), radiobiological indexes, tumor control probability (TCP) and normal tissue complication probability (NTCP) were analysed and compared for planning target volumes (PTVs) and organs at risk (OAR) studied. Results: Important differences in DVH were found. OAR received higher dose levels when a 5.5 mm detector was used to measure profiles compared to the case in which a 2.0 mm detector was used. A 2 Gy increment in the mean rectal dose was found when the larger detector was used. In the same way, NTCP of brain stem in hypophysis chordoma treatments was doubled when this detector was used. Conclusion: The current use of ionisation chambers of about 5 mm active diameter to get the necessary data to model treatment machines in radiotherapy treatment planning systems (TPS) implies a significant overirradiation of OAR close to the PTV in 3D-CRT treatments due to errors in the measured penumbra of beam profiles. To avoid this overirradiation, the measured profiles should either being acquired with a suitable detector size (2-3 mm active diameter) or being deconvoluted

Additional details

Identifiers

DOI
10.1016/j.radonc.2004.10.012;
PII
S0167-8140(04)00514-6;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
74
Journal Issue
3
Journal Page Range
p. 315-322
ISSN
0167-8140
CODEN
RAONDT

Optional Information

Copyright
Copyright (c) 2005 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.