Studies on Section XI ultrasonic repeatability
Description
A block representative of a nuclear component has been welded containing intentional defects. Acoustic emission data taken during the welding correlate well with ultrasonic data. Repetitive ultrasonic examinations have been performed by skilled operators using a procedure based on that desribed in ASME Section XI. These examinations were performed by different examination teams using different ultrasonic equipment in such a manner that the effects on the repeatability of the ultrasonic test method caused by the operator and by the use of different equipment could be estimated. It was tentatively concluded that when considering a large number of inspections: (1) there is no significant difference in indication sizing between operators, and (2) there is a significant difference in amplitude and defect sizing when instruments having different, Code acceptable operating characteristics are used. It was determined that the Section XI sizing parameters follow a bivariate normal distribution. Data derived from ultrasonically and physically sizing indications in nuclear components during farication show that the Section XI technique tends to overestimate the size of the reflectors
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A08/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 170 p.
- Report number
- EPRI-NP--1858
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12632833
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- DEFECTS; EXPERIMENTAL DATA; PERFORMANCE; PERSONNEL; REACTOR COMPONENTS; RELIABILITY; SIZE; SPECIFICATIONS; ULTRASONIC TESTING; WELDED JOINTS
- Descriptors DEC
- ACOUSTIC TESTING; DATA; INFORMATION; JOINTS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; NUMERICAL DATA; TESTING