Published October 2011 | Version v1
Journal article

Accuracy of CT angiography in the assessment of the circle of Willis: comparison of volume-rendered images and digital subtraction angiography

  • 1. Dept. of Radiology, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)
  • 2. Dept. of Radiology, Kangwon National Univ. College of Medicine, Chuncheon, Kangwon-do (Korea, Republic of)
  • 3. Dept. of Neurosurgery, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)
  • 4. Dept. of Thoracic Surgery, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)
  • 5. Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of)

Description

Background Computed tomography angiography (CTA) is increasingly used for non-invasive imaging of the cerebrovascular diseases. Purpose To evaluate the accuracy of CTA in the assessment of the variation of the segment calibers of the circle of Willis. Material and Methods One hundred and 17 patients with acute SAH (51 men and 66 women, mean age 50.9 years) who underwent CTA using a 16 detector-row CT scanner and DSA were evaluated retrospectively. The CTA and DSA studies were performed within 24 h after the onset of symptoms and within 24 h of each other. A total of 819 arterial segments (A-comA, right and left A1 segment, right and left P-com A, and right and left P1 segment) of the circle of Willis were determined to be aplastic (grade 1), hypoplastic (grade 2), or normal-sized (grade 3) by blinded observers evaluating CTA volume-rendered images. The CTA results were then compared with findings on the corresponding DSA images (reference standard). Results The overall agreement between CTA and DSA was 92.4%. We had 62 (7.6%) cases of disagreement (58 cases of under-estimation and four cases of over-estimation by CTA) between tow modalities. The sensitivity and specificity of CTA in the detection of aplastic and normal-sized segments were more than 90%. In contrast, subgroup analysis of the hypoplastic segments showed a sensitivity of 52.6% and a specificity of 98.2%. Conclusion CTA is highly accurate in the assessment of anatomical variations of the circle of Willis; however, its sensitivity is limited in depicting hypoplastic segments

Availability note (English)

Available from DOI: http://dx.doi.org/10.1258/ar.2011.110223

Additional details

Identifiers

Publishing Information

Journal Title
Acta Radiologica (online)
Journal Volume
52
Journal Issue
8
Journal Page Range
p. 889-893
ISSN
1600-0455

INIS