Published 1979 | Version v1
Report Open

Self-magnetically insulated power flow

Description

Electromagnetic power transport through self-magnetically insulated vacuum transmission lines has been developed into a useful and reliable technology. A power density of 160 TW/m2 has been transported at approx. 100 percent efficiency over six meters. The theoretical understanding of power flow through lines of constant cross section has progressed through analytical theory and 2-D electromagnetic particle simulations. However, work needs to be done on the effects of line transitions in which the cross section changes in the direction of power flow. The major features of our present understanding will be reviewed and some promising hypotheses now under investigation will be presented

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

11498122.pdf

Files (274.5 kB)

Name Size Download all
md5:6abd89505ea3bb53dc0cefe1ef86f07e
274.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
SAND--79-0932C

Conference

Title
Pulsed power conference.
Dates
12 - 14 Jun 1979.
Place
Lubbock, TX, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
11498122
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference, Numerical Data
Descriptors DEI
ACCELERATORS; ELECTRON BEAMS; GRAPHS; INERTIAL CONFINEMENT; NUMERICAL DATA; POWER SUPPLIES; POWER TRANSMISSION
Descriptors DEC
BEAMS; CONFINEMENT; DATA; DATA FORMS; ELECTRONIC EQUIPMENT; INFORMATION; LEPTON BEAMS; PARTICLE BEAMS

Optional Information

Secondary number(s)
CONF-790622--6.