Histopathologic response after hydrophilic polyethylene glycol-coating stent and hydrophobic octadecylthiol-coating stent implantations in porcine coronary restenosis model
Creators
- 1. Pusan National University Hospital. Division of Cardiology, Medical Research Institute, Department of Internal Medicine (Korea, Republic of)
- 2. Pohang University of Science and Technology (POSTECH). Department of Chemical Engineering (Korea, Republic of)
Description
Device-related problems of drug-eluting stents, including stent thrombosis related to antiproliferative drugs and polymers, can cause adverse events such as inflammation and neointimal hyperplasia. Stent surface modification, wherein the drug and polymer are not required, may overcome these problems. We developed hydrophilic polyethylene glycol (PEG)-coating and hydrophobic octadecylthiol (ODT)-coating stents without a drug and polymer and evaluated their histopathologic response in a porcine coronary restenosis model. PEG-coating stents (n = 12), bare-metal stents (BMS) (n = 12), and ODT-coating stents (n = 10) were implanted with oversizing in 34 porcine coronary arteries. Four weeks later, the histopathologic response, arterial injury, inflammation, and fibrin scores were analyzed. A p value < 0.05 was considered statistically significant. There were significant differences in the internal elastic lamina area, lumen area, neointimal area, percent area of stenosis, arterial injury score, inflammation score, and fibrin score among the groups. Compared to the BMS or ODT-coating stent group, the PEG-coating stent group had significantly increased internal elastic lamina and lumen area (all p < 0.001) and decreased neointimal area and percent area of stenosis (BMS: p = 0.03 and p < 0.001, respectively; ODT-coating: p = 0.013 and p < 0.001, respectively). Similarly, the PEG-coating group showed significantly lower inflammation and fibrin scores than the BMS or ODT-coating groups (BMS: p = 0.013 and p = 0.007, respectively; ODT-coating: p = 0.014 and p = 0.008, respectively). In conclusion, hydrophilic PEG-coating stent implantation was associated with lower inflammatory response, decreased fibrin deposition, and reduced neointimal hyperplasia than BMS or hydrophobic ODT-coating stent implantation in the porcine coronary restenosis model.
Additional details
Identifiers
Publishing Information
- Journal Title
- Journal of Materials Science. Materials in Medicine
- Journal Volume
- 31
- Journal Issue
- 12
- Journal Page Range
- vp.
- ISSN
- 0957-4530
- CODEN
- JSMMEL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 55078207
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BLOOD COAGULATION; COATINGS; COMPARATIVE EVALUATIONS; CORONARIES; DRUGS; FIBRIN; FIBRINOGEN; GRAFTS; HEMATOXYLIN; INFLAMMATION; INJURIES; MODIFICATIONS; POLYETHYLENE GLYCOLS; SURFACES; THROMBOSIS
- Descriptors DEC
- ALCOHOLS; AROMATICS; ARTERIES; BLOOD COAGULATION FACTORS; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DISEASES; DYES; ETHYLENE GLYCOLS; EVALUATION; GLOBULINS; GLYCOLS; HETEROCYCLIC COMPOUNDS; HETEROCYCLIC OXYGEN COMPOUNDS; HYDROCARBONS; HYDROXY COMPOUNDS; ORGANIC COMPOUNDS; ORGANIC OXYGEN COMPOUNDS; ORGANIC POLYMERS; ORGANS; PATHOLOGICAL CHANGES; PHENOLS; POLYMERS; POLYPHENOLS; PROTEINS; PYRANS; SCLEROPROTEINS; SYMPTOMS; TRANSPLANTS; VASCULAR DISEASES
Optional Information
- Copyright
- Copyright (c) 2020 © Springer Science+Business Media, LLC, part of Springer Nature 2020