Published July 2003 | Version v1
Journal article

Calibration of thoron monitors

Creators

  • 1. Nanhua Univ., Hengyang (China). Research Inst. of Uranium Mining

Description

The calibration of various kinds of thoron monitor has been investigated. A main problem lies in that the emanation percentage of various kinds of thoron standard source is always less than 100%. In order to determine the emanation percentage accurately, an absolute measurement method with airflow-through scintillation cell was established, and its feasibility was verified by a comparative measurement with the activated charcoal-γ spectrometer method. This will make the calibration accuracy of thoron monitors rising

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
26
Journal Issue
7
Journal Page Range
p. 561-563
ISSN
0253-3219