Experience gained from equipment qualification inspections

Description

This paper describes issues which have been identified during equipment qualification inspections. Generic qualification information is discussed first, such as qualification bases, utility/supplier interfaces, file auditability, and generic environmental qualification. Next, technical strategies with specific examples are discussed. Issues covered include functional performance requirements, post accident qualification, similarity, installation and interfaces, maintenance, aging, and testing. Finally, additions and deletions to equipment qualification master lists and environmental enveloping are discussed

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - GPO as TI86016107.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
11 p.
Report number
SAND--86-0723C

Conference

Title
Operability of nuclear power systems in normal and adverse environments meeting.
Dates
29 Sep - 3 Oct 1986.
Place
Albuquerque, NM (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
18058191
Subject category
S99: GENERAL AND MISCELLANEOUS; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AGING; EQUIPMENT; INSPECTION; MAINTENANCE; NUCLEAR POWER PLANTS; QUALITY ASSURANCE; TESTING
Descriptors DEC
NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Secondary number(s)
CONF-860908--7.