Radioimmunoassay of secretin in plasma
Creators
- 1. Saint Vincent's Hospital, Sydney (Australia). Bruce Hall Dept. Gastroenterology
- 2. Saint Vincent's Hospital, Sydney (Australia). Garvan Inst. of Medical Research
Description
A sensitive, specific and reproducible radioimmunoassay for secretin is described. Antibodies were readily produced against low microgram quantities of synthetic secretin. The secretin antibodies did not cross-react with the structurally similar G.I.P., V.I.P., or glucagon. Synthetic secretin was iodinated using chloramine 'T' and purified by a two-stage procedure incorporating gel filtration and gradient elution from a cation exchange column. Plasma samples were found to produce variable interference in the assay necessitating the incorporation of secretin-free 'blanks' for each patient's plasma. Production of secretin-free plasma was by incubation of plasma samples at 370C for 96 hours. The sensitivity of the assay was 12.5-25 pg/ml. Normal fasting secretin levels were 21 +- S.E. 7 pg/ml. A mean rise in plasma secretin to 220 pg/ml was observed after intraduodenal acidification. (orig.)
Abstract (German)
Es wird ein empfindlicher, spezifischer und reproduzierbarer Radioimmunoassay fuer Sekretin beschrieben. Antikoerper gegen geringe Mengen von Sekretin C (im Mikrogrammbereich) wurden rasch produziert. Die Sekretin-Antikoerper zeigten keine Kreuzreaktion mit dem strukturell aehnlichen G.I.P., V.I.P oder Glukagon. Synthetisches Sekretin wurde mit Chloramin 'T' jodiert und in einem Zweistufenprozess durch Gelfiltration und stufenweise Eluierung in einer Kationenaustauschersaeule gereinigt. Plasmaproben erzeugten variable Interferenzen im Assay, so dass eine Inkorporierung von sekretinfreien 'blanks' im Plasma jedes Patienten notwendig wurde. Sekretinfreies Plasma wurde durch Inkubation von Plasmaproben bei 370C ueber 96 Std. dargestellt. Die Empfindlichkeit des Assay war 12,5-25 pg/ml. Normale Nuechternwerte fuer Sekretin waren 21 +- S.E. 7 pg/ml. Nach intraduodenaler Acidifizierung wurde ein mittlerer Anstieg des Plasmasekretin auf 220 pg/ml festgestellt. (orig.)Additional details
Identifiers
Publishing Information
- Journal Title
- Hormone and Metabolic Research
- Journal Volume
- 8
- Journal Issue
- 05
- Series
- Horm. Metab. Res.
- Journal Page Range
- 361-365
- ISSN
- 0018-5043
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 8296408
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- ANTIGEN-ANTIBODY REACTIONS; BLOOD PLASMA; DIAGNOSTIC TECHNIQUES; GLUCAGON; IODINE 125; RADIOIMMUNOASSAY; RADIOPHARMACEUTICALS; SECRETIN; SMALL INTESTINE; TEMPERATURE DEPENDENCE
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BIOLOGICAL MATERIALS; BLOOD; BODY; BODY FLUIDS; DAYS LIVING RADIOISOTOPES; DIGESTIVE SYSTEM; DRUGS; ELECTRON CAPTURE RADIOISOTOPES; GASTROINTESTINAL TRACT; HORMONES; INTERMEDIATE MASS NUCLEI; INTESTINES; IODINE ISOTOPES; ISOTOPE APPLICATIONS; ISOTOPES; LABELLED COMPOUNDS; NUCLEI; ODD-EVEN NUCLEI; ORGANIC COMPOUNDS; ORGANS; PEPTIDE HORMONES; PEPTIDES; POLYPEPTIDES; PROTEINS; RADIOACTIVE MATERIALS; RADIOISOTOPES; TRACER TECHNIQUES
Optional Information
- Notes
- 6 figs.; 21 refs.; Updated automatically by Metadata and Full-Text Enrichment Agent