Published 2022 | Version v1
Miscellaneous

CT image quality metrics implementation during thorax SPECT/CT clinic studies

  • 1. Instituto Superior de Ciencias y Tecnologías Aplicadas, Universidad de la Habana, La Habana (Cuba)
  • 2. Dept. de Medicina Nuclear, Hospital Hermanos Ameijeiras, La Habana (Cuba)
  • 3. Dept. de Medicina Nuclear, Instituto Nacional de Hematología, La Habana (Cuba)

Description

In hybrid studies, the total patient's radiation dose and the image's quality are the results of the two technologies. This work studied the implementation and evaluation of some CT image´s quality metrics like noise, contrast to noise ratio(CNR) and resolution through the half maximum (FWHM) of different anatomical structure, and their preliminary relationship with patient's radiation dose parameters including the volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE),during thorax clinical studies, in a Mediso SPECT/CT equipment.20 clinical SPECT/CT studies were analyzed using a homemade computed subroutine. The SSDE preliminary result were between 2,6-23,6mGy. The different thorax structures typical noise varied from 2,1 to 42,3% among patient, showing very different behaviors between different tissues, example lungs and esophagus had average noise less than 5%. The CNR showed statistical difference between studies, varying from 1 to 57. The same structure FWHM estimation ranged between 14,8-50,5% during different studies, showing statistical differences. The SSDE and FWHM showed a statistically significant Pearson correlation coefficient of -0,454 (p=0,045). Conclusions:the SSDE inversely correlated with some of studied CT image´s quality metrics. The FWHM clinical estimation of different anatomical structure is viable and showed the capability to detect image characteristic which could be direct related with their quality and clinical analysis. (author)

Part of:
Proceedings of the 26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics

Additional details

Additional titles

Original title (Portuguese)
Implementación de métricas de calidad de imagen de CT en estudios clínicos SPECT/CT de tórax

Publishing Information

Imprint Title
Proceedings of the 26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics
Imprint Pagination
177 p.
Journal Page Range
9 p.
Report number
INIS-BR--24586

Conference

Title
26. Brazilian congress on medical physics; 9. Latin American Congress on medical physics
Dates
8-11 Jun 2022
Place
Fortaleza, CE (Brazil)

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
54104415
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CHEST; COMPUTERIZED TOMOGRAPHY; IMAGES; METRICS; QUALITY CONTROL; RADIATION DOSES; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
Descriptors DEC
BODY; COMPUTERIZED TOMOGRAPHY; CONTROL; DIAGNOSTIC TECHNIQUES; DOSES; EMISSION COMPUTED TOMOGRAPHY; TOMOGRAPHY

Optional Information

Notes
Imprint:Anais do 26. Congresso brasileiro de f#Latin Small Letter I With Acute#sica m#Latin Small Letter E With Acute#dica; 9. Congresso latino-americano de f#Latin Small Letter I With Acute#sica m#Latin Small Letter E With Acute#dica