Published July 1982 | Version v1
Report Restricted

Final report on the scientific and engineering design of a soft X-ray diode array diagnostic system for JET (KJ 1)

Description

This report describes the Soft-X-Ray Diode Array Diagnostic System for JET. It was designed by the IPP under an Article 14 contract for Phase I. The diagnostics will be capable of measuring the Soft-X-ray emission from H and D plasmas in JET with high resolution in space and time. Two slot-hole cameras with 150 detectors viewing the same toroidal cross-section of the plasma are foreseen. Thin beryllium and aluminium filters in the line of sight of the detectors allow simultaneous measurements within different limits of the X-ray spectrum. Heavy shielding against neutron and gamma radiation is provided in order to reduce radiation induced signals and to increase detector lifetimes. The signals of 100 detectors can be simultaneously sampled with a sampling rate variable up to 250 KHz and stored in 12 bit memories of about 20 Kwords size. (orig.)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
50 p.
Report number
IPP--1/209

Optional Information

Contract/Grant/Project number
Contract JBO/9010
Notes
Reprint of IPP-JET--6.