Preliminary research on measuring grease stain in petroleum pipeline using thermal neutron transmission gauge

  • 1. Nanping Teachers College, Nanping, Fujian (China). Dept. of Electronic Engineering
  • 2. Nanjing Univ., Nanjing (China). Dept. of Physics

Description

The principle and experiments on the measurement of grease stain in petroleum pipeline using the thermal neutron gauge were reported. the designed simulated experimental device was aimed at small pipelines. It mainly consists of a thermal neutron beam emissive device and a thermal neutron beam detecting device. The experiment result indicates that it is very sensitive if the thermal neutron beam is used and its measuring accuracy is 1.6 mm. If the total neutron beam is used, it is convenient, but is not so sensitive, and its accuracy is 4.4 mm. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
27
Journal Issue
11
Journal Page Range
p. 870-872
ISSN
0253-3219