Published July 1, 2012
| Version v1
Report
Individual RF Test Results of the Cavities Used in the First US-built ILC-type Cryomodule
Description
Eight 1.3-GHz, nine-cell SRF cavities have been installed in a cryomodule intended to demonstrate the ILC design goal of 31.5 MV/m. These cavities all underwent two types of individual RF testing: a low-power continuous-wave test of the 'bare' cavity and a high-power pulsed test of the 'dressed' cavity. Presented here is a discussion of the results from these tests and a comparison of their performance in the two configurations.
Availability note (English)
Available from https://misportal.jlab.org/ul/publications/downloadFile.cfm?pub_id=11613; PURL: https://www.osti.gov/servlets/purl/1048036/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- vp.
- Report number
- JLAB-ACC--12-1516
Conference
- Title
- 3. International Particle Accelerator Conference
- Acronym
- IPAC 2012
- Dates
- 20-25 May 2012
- Place
- New Orleans, LA (United States)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 43127605
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CAVITIES; DESIGN; PERFORMANCE; TESTING
Optional Information
- Contract/Grant/Project number
- AC02-07CH11359
- Funding organization
- USDOE Office of Science (United States)
- Secondary number(s)
- DOE/OR--23177-2265