Description

Electrical Impedance Tomography (EIT) systems are used to image tissue bio-impedance. EIT provides a number of features making it attractive for use as a medical imaging device including the ability to image fast physiological processes (>60 Hz), to meet a range of clinical imaging needs through varying electrode geometries and configurations, to impart only non-ionizing radiation to a patient, and to map the significant electrical property contrasts present between numerous benign and pathological tissues. To leverage these potential advantages for medical imaging, we developed a modular 32 channel data acquisition (DAQ) system using National Instruments' PXI chassis, along with FPGA, ADC, Signal Generator and Timing and Synchronization modules. To achieve high frame rates, signal demodulation and spectral characteristics of higher order harmonics were computed using dedicated FFT-hardware built into the FPGA module. By offloading the computing onto FPGA, we were able to achieve a reduction in throughput required between the FPGA and PC by a factor of 32:1. A custom designed analog front end (AFE) was used to interface electrodes with our system. Our system is wideband, and capable of acquiring data for input signal frequencies ranging from 100 Hz to 12 MHz. The modular design of both the hardware and software will allow this system to be flexibly configured for the particular clinical application.

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/434/1/012081

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
434
Journal Issue
1
Journal Page Range
[4 p.]
ISSN
1742-6596

Conference

Title
15. international conference on electrical bio-impedance (ICEBI); 14. conference on electrical impedance tomography (EIT)
Dates
22-25 Apr 2013
Place
Heilbad Heiligenstadt (Germany)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44119044
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DATA ACQUISITION SYSTEMS; DESIGN; ELECTRICAL PROPERTIES; ELECTRODES; GEOMETRY; HARMONICS; IMPEDANCE; SIGNALS; SYNCHRONIZATION; TOMOGRAPHY
Descriptors DEC
DIAGNOSTIC TECHNIQUES; MATHEMATICS; OSCILLATIONS; PHYSICAL PROPERTIES