Analysis of thermal fluctuations in the Westinghouse Canada Water Loop to determine flow transit delay times using a transfer function cross-correlation technique
Description
Aerojet Nuclear Company performed an experiment at the Westinghouse Canada Ltd. water loop to try to verify the performance of a Transit Time Flowmeter to ultimately measure two-phase flow rates. The recorded data from that experiment were made available and analyzed at Argonne National Laboratory using a transfer function cross-correlation technique. The theoretical background for the transfer function method of analysis and the results of the data analysis are presented. Strong correlation peaks, which are very close to the expected delay times, were found in certain portions of the data