Published October 2013 | Version v1
Journal article

Design of diagnostic system for neutron penumbral imaging based on Shenguang-Ⅲ facility

  • 1. Research Center of Laser Fusion, CAEP, Mianyang (China)

Description

The aperture for neutron penumbral imaging is newly designed in order to reduce the difficulties of fabrication and detecting. Firstly, the source-detector and source-aperture distances are fixed on because of the neutron yield of Shenguang-Ⅲ facility. Then, base on the sharpness and isoplanaticity of the point spread function, the radii of the aperture are optimized. Finally, the resolution of the system is analysed, and the distortions induced by the aperture-fabrication error and misalignment are estimated by the simulation. According to the results, a resolution of 15 μm can be satisfied, the fabrication error should be limited to a maximum of 0.1, the precision of alignment should be better than 60 μm, the aperture rotation should be within 0.35 mrad, and the source-aperture distance error should be less than 1 mm. (authors)

Additional details

Publishing Information

Journal Title
High Power Laser and Particle Beams
Journal Volume
25
Journal Issue
10
Journal Page Range
p. 2604-2610
ISSN
1001-4322

INIS

Optional Information

Notes
12 figs., 1 tab., 19 refs.