Published February 1, 1987 | Version v1
Journal article

Application of LiF thermoluminescence dosimeter powders in neutron gamma mixed field dosimetry and dose mapping in the thermal column of a TRIGA Mk II reactor

  • 1. Atominstitut der Oesterreichischen Universitaeten, Vienna

Description

Thermal neutron and fission product gamma dose rates at different positions in the horizontal thermal column of a TRIGA Mk-II reactor, as well as in a cadmium cladded cylindrical cavity embedded in a borated wooden box placed in the thermal column, were assessed with TLD-600 and TLD-700 dosimeter powders. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
254
Journal Issue
1
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
182-185
ISSN
0168-9002
CODEN
NIMAE