Calibration of Kerma Area Product Meters with a Patient Dose Calibrator

  • 1. Radiation and Nuclear Safety Authority (STUK), Helsinki (Finland)
  • 2. University Hospital of Kuopio, Kuopio (Finland)

Description

Kerma area product (KAP) meters used in X ray imaging for monitoring patient exposure were calibrated using different reference meters. Typically, the reference KAP value is the product of the air kerma and the X ray field size. In the tandem method, the reference value is measured with another KAP meter; in this study, a large KAP meter of novel type, the patient dose calibrator (PDC), was used for this purpose. The properties of the PDC meter were studied and the use of the meter as a reference meter was reviewed throughout the whole train of events from calibration in a secondary standard dosimetry laboratory to using the meter in clinical situations. Compared to conventional KAP meters, the advantages of the PDC are the lower energy dependence of response and the possibility to use larger field sizes. In laboratory measurements, the properties of the PDC meter were proved suitable to be used as a reference meter. The uncertainty related to the differences in X ray tube output used in calibration at the laboratory and in measurements at the clinic is highlighted. The calibration coefficients for field KAP meters calibrated by the PDC meter and by other meters were congruent on the average within 4%. Clinical measurements emphasized the need for in situ calibration of clinical KAP meters. Particularly in the under-couch situation, the calibration should be performed with the couch in the beam. (author)

Part of:
Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS). Proceedings of an International Symposium. V. 2

Additional details

Publishing Information

Publisher
IAEA
Imprint Place
Vienna (Austria)
ISBN
978-92-0-116210-6
Imprint Title
Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS). Proceedings of an International Symposium. V. 2
Imprint Pagination
495 p.
Series
Proceedings Series
Journal Page Range
p. 3-19
ISSN
0074-1884

Conference

Title
International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry
Acronym
IDOS 2010
Dates
9-12 Nov 2010
Place
Vienna (Austria)

INIS

Country of Publication
Austria
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43009140
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CALIBRATION; KERMA; METERS; MONITORING; PATIENTS; RADIATION DOSES; SSDL; X RADIATION
Descriptors DEC
DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; RADIATIONS

Optional Information

Contract/Grant/Project number
Project IAEA E2.10.08
Notes
6 figs., 1 tab., 14 refs. Imprint:In two volumes; A CD-ROM of the contributed papers accompanies these proceedings.
Secondary number(s)
STI/PUB--1514(vol.2); IAEA-CN--182