Published September 1986 | Version v1
Report

A national survey of doses to patients undergoing a selection of routine x-ray examinations in English hospitals

  • 1. National Radiological Protection Board, Chilton (UK)
  • 2. Newcastle General Hospital (UK). Regional Medical Physics Dept.

Description

Wide variations have been observed for many of the measured and calculated doses during each examination, with range factors between the extreme values frequently in excess of 100 (average per capita annual dose of about 300 μSv). The majority of measurements in each case are, however, generally covered by a much smaller factor of less than five. Significant differences are also apparent between mean doses determined at the individual hospitals participating in the survey, with factors of over 10 not uncommon between corresponding mean values. The present measurements have included no assessment of image quality during examinations. (author)

Availability note (English)

Available from H.M. Stationery Office, London, price Pound9.00.

Additional details

Publishing Information

ISBN
0 85951 275 4
Imprint Pagination
169 p.
Report number
NRPB-R--200

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
18056643
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; NUCLEAR MEDICINE; PATIENTS; POPULATIONS; RADIATION DOSES; UNITED KINGDOM
Descriptors DEC
DEVELOPED COUNTRIES; DIAGNOSTIC TECHNIQUES; EUROPE; MEDICINE

Optional Information

Contract/Grant/Project number
Contract B10-387-80-UK; B16-135-UK