Published 1977 | Version v1
Book

Electronic device for automatic control of exposure in radiography

  • 1. Bhabha Atomic Research Centre, Bombay (India). Isotope Div.

Description

An electronic instrument for calculating and controlling exposure in radiography practice using radioisotopes is described. When using this equipment, only factor to be known is the dose required by the film for a given density and the thickness of material inspected. It eliminates all the problems arising out of various parameters such as source decay etc in the conventional procedure for calculating exposure time. Principle of operation, the electronic circuitry adopted and the functional aspects of the system are described in detail. Exposure doses for different industrial films have been related to the instrumental readouts. The system reproducibility and reliability have been evaluated. The advantages and limitations of the present system and the future development to overcome the problems are indicated. (author)

Additional details

Publishing Information

Publisher
Department of Atomic Energy.
Imprint Place
Bombay
Imprint Title
Proceedings of the national symposium on industrial isotope radiography [held at] Tiruchirapalli [during] February 26-27, 1976
Journal Page Range
p. 334-345.

Conference

Title
National symposium on industrial isotope radiography.
Dates
26 - 27 Feb 1976.
Place
Tiruchirapalli, India.