Published September 1992 | Version v1
Journal article

Optimization of dynamic terms in core overtemperature delta-T trip function

  • 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Description

The characteristics of dynamic terms in the core overtemperature delta-T trip function are investigated for various time constants and the effects on the trip setpoint are studied for the uncontrolled RCCA bank withdrawal at power event by using the NLOOP and the PUMA code. Based on this study, a procedure determining the optimal dynamic term is suggested and accordingly the optimum time constants are determined for the KORI 3 and 4 transition core. It reveals that the vessel average temperature lead-lag term is the most sensitive in DNB trip setpoint and the optimized time constants are 21 seconds for for lead and 4 seconds for lag. (Author)

Additional details

Publishing Information

Journal Title
Journal of the Korean Nuclear Society
Journal Volume
24
Journal Issue
3
Journal Page Range
p. 236-242.
ISSN
0372-7327
CODEN
WJHKAW