Published November 1, 2016 | Version v1
Journal article

Coupled-resonator-induced transparency in two microspheres as the element of angular velocity sensing

  • 1. Key Laboratory of Instrumentation Science and Dynamic Measurement of Ministry of Education, North University of China, Taiyuan 030051 (China)

Description

We proposed a two-coupled microsphere resonator structure as the element of angular velocity sensing under the Sagnac effect. We analyzed the theoretical model of the two coupled microspheres, and derived the coupled-resonator-induced transparency (CRIT) transfer function, the effective phase shift, and the group delay. Experiments were also carried out to demonstrate the CRIT phenomenon in the two-coupled microsphere resonator structure. We calculated that the group index of the two-coupled sphere reaches n g = 180.46, while the input light at a wavelength of 1550 nm. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1674-1056/25/11/114209

Additional details

Publishing Information

Journal Title
Chinese Physics. B
Journal Volume
25
Journal Issue
11
Journal Page Range
[5 p.]
ISSN
1674-1056

INIS

Country of Publication
China
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49016639
Subject category
S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
ANGULAR VELOCITY; MICROSPHERES; OPACITY; PHASE SHIFT; RESONATORS; SPHERES; TRANSFER FUNCTIONS; VISIBLE RADIATION; WAVELENGTHS
Descriptors DEC
ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; EQUIPMENT; FUNCTIONS; OPTICAL PROPERTIES; PHYSICAL PROPERTIES; RADIATIONS; VELOCITY