Published 2011 | Version v1
Miscellaneous

Metal artefact reduction for a dental cone beam CT image using image segmentation and backprojection filters

  • 1. Bou-Ali Sina University, Hamadan, Iran (Iran, Islamic Republic of). Dept. of Computer Engineering
  • 2. University of Adelaide and the Department of Medical Physics, Royal Adelaide Hospital, Australia (Australia). School of Chemistry and Physics

Description

Full text: Due to low dose delivery and fast scanning, the dental Cone Beam CT (CBCT) is the latest technology being implanted for a range of dental imaging. The presence of metallic objects including amalgam or gold fillings in the mouth produces an intuitive image for human jaws. The feasibility of a fast and accurate approach for metal artefact reduction for dental CBCT is investigated. The current study investigates the metal artefact reduction using image segmentation and modification of several sinigrams. In order to reduce metal effects such as beam hardening, streak artefact and intense noises, the application of several algorithms is evaluated. The proposed method includes three stages: preprocessing, reconstruction and post-processing. In the pre-processing stage, in order to reduce the noise level, several phase and frequency filters were applied. At the second stage, based on the specific sinogram achieved for each segment, spline interpolation and weighting backprojection filters were applied to reconstruct the original image. A three-dimensional filter was then applied on reconstructed images, to improve the image quality. Results showed that compared to other available filters, standard frequency filters have a significant influence in the preprocessing stage (ΔHU = 48 ± 6). In addition, with the streak artefact, the probability of beam hardening artefact increases. t e post-processing stage, the application of three-dimensional filters improves the quality of reconstructed images (See Fig. I). Conclusion The proposed method reduces metal artefacts especially where there are more than one metal implanted in the region of interest.

Part of:
Abstract EPSM-ABEC 2011 Conference

Additional details

Publishing Information

Publisher
Australasian College of Physical Scientists and Engineers in Medicine
Imprint Place
Darwin (Australia)
Imprint Title
Abstract EPSM-ABEC 2011 Conference
Imprint Pagination
79 p.
Journal Page Range
p. 626

Conference

Title
The Engineering and Physical Sciences in Medicine and the Australian Biomedical Engineering Conference
Acronym
EPSM-ABEC 2011
Dates
14-18 Aug 2011
Place
Darwin (Australia)

INIS

Country of Publication
Australia
Country of Input or Organization
Australia
INIS RN
44026411
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CAT SCANNING; DENTISTRY; DIAGNOSTIC TECHNIQUES; IMAGE PROCESSING; IMAGES; METALS; TEETH
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; ELEMENTS; MEDICINE; ORAL CAVITY; PROCESSING; TOMOGRAPHY

Optional Information