PANDA asymmetric-configuration passive decay heat removal test results

  • 1. Paul Scherrer Institut, Villigen (Switzerland)

Description

PANDA is a large-scale, low-pressure test facility for investigating passive decay heat removal systems for the next generation of LWRs. In the first series of experiments, PANDA was used to examine the long-term LOCA response of the Passive Containment Cooling System (PCCS) for the General Electric (GE) Simplified Boiling Water Reactor (SBWR). The test objectives include concept demonstration and extension of the database available for qualification of containment codes. Also included is the study of the effects of nonuniform distributions of steam and noncondensable gases in the Dry-well (DW) and in the Suppression Chamber (SC). 3 refs., 9 figs