Critical heat fluxes on vertical tube inner surface in water flowing upward. Pt. 3. Effect of tube length on CHF

  • 1. Kyoto Univ., Dept. of Energy Science and Technology, Uji, Kyoto (Japan)
  • 2. Kyoto Univ., Institute of Advanced Energy, Uji, Kyoto (Japan)

Description

The critical heat fluxes (CHFs) in subcooled boiling of water in a short vertical tubes with the inner diameter of 9 mm, the lengths of 100 and 150 mm were measured for the flow velocities ranging from 4.0 to 13.3 m/s, at the pressure of 800 kPa. The CHFs versus the inlet subcooling at each flow velocity were divided into first, second and third groups, which were similar to the cases of the tube length of 50 mm. The CHFs decrease as L increase. The effect of tube lengths on CHF is discussed. (author)

Additional details

Publishing Information

Journal Title
Nippon Dennetsu Shinpojiumu Koen Ronbunshu
Journal Volume
38
Journal Page Range
p. 589-590
CODEN
NDSRD4

Conference

Title
38. national heat transfer symposium of Japan
Dates
23-25 May 2001
Place
Saitama (Japan)

Optional Information

Notes
This CD-ROM can be used for WINDOWS, MACINTOSH; Acrobat Reader is included; Data in PDF format, 38s_g222.pdf; 5 refs., 7 figs.