Description of the Seibersdorf incineration plant for low level waste

  • 1. Oesterreichisches Forschungszentrum Seibersdorf G.m.b.H. Hauptabteilung Abfallverarbeitung

Description

After a description of the design and the construction principles of the incinerator building, the furnace and its attached auxilary devices are explained. The incinerator is layed out for low level wastes. It has a vertical furnace, operates with discontinuous feeding for trashes with heat-values between 600 and 10000 kcal/kg waste. The maximum throughput amounts 40 kg/h. The purification of the off-gas is guaranteed by a multistage filter system: 2 stages with ceramic candles, cooling column and a HEPA-filter system. The control of the off-gas cleaning is carried out by a stack instrumentation, consisting of an aerosol-, gas-, Iodine- and Tritium-monitor; the building is surveilled by doserate- and aerosolmonitors. (Author)

Availability note (English)

MF available from INIS under the Report Number.

Files

17088953.pdf

Files (1.1 MB)

Name Size Download all
md5:28af35fbff372336caa386aadac41992
1.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
46 p.
Report number
OEFZS--4373

Optional Information

Secondary number(s)
AV--18/86.