Published November 1991 | Version v1
Journal article

Corrosion of Alloy 600 in reduced-sulfur containing solutions at high temperatures

  • 1. Nuclear Fuel Industries Ltd., Tokyo (Japan)

Description

It is well known that reduced sulfur species lead to intergranular attack (IGA) of sensitized Alloy 600 at low temperature, however the effect of these species on Alloy 600 at high temperature is not clear. Static autoclave tests were performed to investigate the effect of reduced sulfur (CaS2O3) on the high temperature aqueous corrosion of Alloy 600. The results show that reduced sulfur can cause severe corrosion on Alloy 600 in high temperature water. (author)

Additional details

Publishing Information

Journal Title
Zairyo To Kankyo
Journal Volume
40
Journal Issue
11
Series
Zairyo To Kankyo.
Journal Page Range
736-741
ISSN
0917-0480
CODEN
ZAKAE

Conference

Title
4. international symposium on environmental degradation of materials in nuclear power systems.
Dates
6-10 Aug 1989.
Place
Jekyll Island, GA (United States).