Published April 2002 | Version v1
Journal article

Design and construction of a thin septum magnet prototype for injection of SSRF storage ring

  • 1. Chiense Academy of Sceinces, Beijing (China). Inst. of High Energy Physics
  • 2. Nanjing Univ., Nanjing (China). Dept. of Physics

Description

According to the storage ring injection requirements of Shanghai Synchrotron Radiation Facility (SSRF), an eddy current septum magnet prototype has been firstly constructed in China. All measured specifications of the magnet are very well satisfied with the requirements of the storage ring injection. Some key issues of the design and construction of the septum magnet are discussed, the measured performances of the septum magnet are given and some constructive suggestions to improve the performance of the septum are proposed

Additional details

Additional titles

Augmented title (English)
The SSRF is stated for Shanghai Synchrotron Radiation Facility

Publishing Information

Journal Title
High Energy Physics and Nuclear Physics
Journal Volume
26
Journal Issue
4
Journal Page Range
p. 423-429
ISSN
0254-3052

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
34025863
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
BEAM EXTRACTION; BEAM INJECTION; DESIGN; EDDY CURRENTS; PERFORMANCE; SEPTUM MAGNETS; SPECIFICATIONS; STORAGE RINGS
Descriptors DEC
CURRENTS; ELECTRIC CURRENTS; EQUIPMENT; MAGNETS